TEST OF POWER TRANSFORMERS

Power-Transformar

High Voltage Power Transformer Testing

HV / EHV TRANSFORMERS

On-site Diagnostic Testing of HV / EHV class of Transformers:
Our experience spans across power transformers of all voltage class upto 1200 kV and rating upto 500 MVA.
Transformer
  • Voltage Ratio and Vector group confirmation test,
  • Frequency Response Analysis (FRA),
  • No-load excitation current measurement
  • Capacitance and dissipation factor measurement of the inner insulation
  • Capacitance and dissipation factor measurement of high-voltage bushings
  • Impedance measurements (short-circuit impedance, zero sequence impedance, FRSL method)
  • Analysis of winding damages with the FRA method
  • Moisture analysis of paper insulation by dielectric method (PDC+ FDS).
  • OLTC operation and dynamic contact resistance measurement
  • Winding Resistance Measurement
  • Thermography , Noise , Vibration Measurement
  • Routine Oil test, DGA, Furan
  • DP test of paper insulation.
  • On line & Off line Partial discharge measurements of transformers

CURRENT TRANSFORMERS

On-site Testing of the HV/EHV class of Current Transformers

It is intended to perform automatic testing by CT Analyser on-site for utilities with very less testing time or by Primary injection test. The following tests can be performed:
CURRENT-TRANSFORMER-600x338
  • Burden & CT winding resistance measurement
  • CT excitation characteristics according to IEC 60044-1, IEC 60044-6 (TPS, TPX, TPY) and IEEE C57.13. for knee-point voltages (up to 15 kV).
  • CT ratio & phase angle error measurement
  • CT phase and polarity measurement
  • Determination of accuracy limiting factor, instrument security factor,
  • Test of CTs for knee-point voltages (up to 15 kV).
  • Capacitance and dissipation factor measurement of the inner insulation
  • Capacitance and dissipation factor measurement of high-voltage bushings
  • Moisture analysis of paper insulation dielectric method (PDC+ FDS)
  • DGA test of oil.
  • On line & Off line Partial discharge measurements of CT.

CVT & PT

On-site Testing of the HV/EHV class of Potential Transformers and CVTs
  • Capacitance and dissipation factor measurement
  • Primary injection & Ratio test.
  • Moisture analysis of paper insulation by dielectric method (PDC+ FDS).
  • IR value with Polarization Index (PI) & Absorption Index (AI),
  • DC Resistance measurement
    On line & Off line Partial discharge measurements.
POWER TRANSFORMERS

FAQs

1. Why is it important to test power transformers? 

Testing power transformers is important because it helps ensure that the components of transformers are working properly and reduces the risk of failure. 

2. What are some common tests performed on power?

Common tests for power transformers include turn ratio resting, insulation resistance testing, power factor testing, and resistance testing. 

3. How often should power transformers be tested? 

Testing transformer oils and insulating oils regularly is standard industry practice. Utility companies typically perform routine electrical testing on a 3-5 year rotation.

4. Who can perform power transformer testing?

Power transformer testing demands expertise and specialized equipment. It must be performed by a professional electrical engineer or technician with the appropriate expertise and experience. 

5. What are the benefits of testing power transformers? 

The testing of power transformers has the following advantages: 

  • Regular testing can help ensure the safety of transformers and reduce the risk of fires or explosions.
  • It saves unexpected repair costs by detecting potential threats earliest. 
  • And helps enhance the performance of the transformer. 

Request A Quote?

Laxmi Associates Vadodara Gujarat Post

ITI Electrician
Experience - 2-3 Years Experience - 10 to 15 positions
Field/Domain - Testing Kit handling & Maintenance at Pan India level with extensive traveling.
Location -PAN India Level.

Account Executive
Having knowledge of Excel, Tally, and GST/bank transaction
Experience (1 to 2 years) Female/Male Candidates

Executive Engineer
For Report & Tender Department
Experience (1to 3 years)(3-male candidates required)
Location-Vadodara manjalpur

Junior and Senior Testing and Commissioning Engineers
Experience - B Tech/ Diploma Electrical Engineers with 2 - 5 Years Experience - 15 positions
Field/Domain -Testing & Commissioning in Transformer, Switch Gears, Switchyard (Relay, Motors, PD/DCRM Generator, Transformers).

Location - PAN India Level.
Kindly send your resume on below the mention mail id

Email: [email protected]
Contact Info. Hemal-09824201737